|   2-6-15-snyatie-i-ustanovka-lyambda-zond-posle-katalizatora.html 2.6.15. Removal and installation a lambda probe after the catalystRemoval 
 
|  | Fig. 2.252. Shtekerny connections for a lambda probe and heating a lambda probe 
 | 
 Disunite electric shtekerny connection 2 (the brown plug) for a lambda probe after the catalyst (fig. 2.252) .
 
|  | Fig. 2.253. Location lambda probe and heating lambda probe 
 | 
 Unscrew a lambda probe after the catalyst 1 by means of the tool from a set of cap keys for a lambda probe (fig. 2.253) .
 Installation The electrical wiring a lambda probe has to be surely fixed on the former installation sites to avoid contact of an electrical wiring with an exhaust pipe. Inhaling moment: 55 N · m. 
 
| NOTE New a lambda probes are greased with adjusting paste; hit of paste on probe case grooves is not allowed. When using being in the use a lambda probe it is allowed to grease with heat-resistant paste only a carving. Hit of this paste on probe case grooves is not allowed.  | 
 
 
 
 |