2.10.16. Removal and installation of roller leversRemoval
For the return installation mark a ratio of roller levers and axes of roller levers.
|
|
Fig. 2.526. Extraction of an axis of the roller lever
|
Take an axis of the roller lever 1 on the party of an admission by means of a stripper from a head of the block of cylinders (fig. 2.526).
Remove roller levers.
Unscrew bolts 4 and 5.
Take an axis of the roller lever 3 on the party of release from GBTs.
Installation
Installation is made in the return sequence, taking into account the following.
|
NOTE
Replace sealing rings of round section 2.
Before installation oil points of support of roller levers.
|
Inhaling moments
Axis of the roller lever to GBTs: 10 N · m.
Carving stopper of an axis of the roller lever to GBTs*: 10 N · m.
* To insert bolts, previously having greased them with a carving varnish; carving varnish.
|