3-4-3-razborka-i-sborka-prochekanennogo-tripoidnogo-sharnira-aar-2600i-ili-3300i.html
3.4.3. Dismantling and assembly of the pro-minted tripoidny AAR 2600i or 3300i hinge
|
Fig. 3.118. Components of the pro-minted tripoidny AAR 2600i or 3300i hinge: 1 – collar; 2 – boot of the Tripod hinge; 3 – collar; 4 – lock ring; 5 – dish-shaped spring; 6 – expansion ring (plastic); 7 – lock ring; 8 – The CV JOINT is external; 9 – bolt; 10 – collar; 11 – boot of the external CV JOINT; 12 – collar; 13 – power shaft; 14 – lock ring; 15 – asterisk of the tripoidny hinge; 16 – lock ring; 17 – a bolt with an internal polyhedron; 18 – hinge element
|
Components of the pro-minted tripoidny AAR 2600i or 3300i hinge are shown in fig. 3.118.
Lubricant of a shaft of the tripoidny hinge
NOTE
When replacing a boot anew grease the hinge.
|
Compression of a collar on the internal hinge
|
Fig. 3.119. Compression of a collar on the internal hinge
|
Boots of hinges from rubber stretch by means of pincers for installation of collars (fig. 3.119).
Nozzle of the external CV JOINT
Clamp a power shaft in a vice with soft inserts.
Remove a big collar and turn out a protective cover of the hinge back.
|
Fig. 3.120. Knocking-out of an internal ring of the CV JOINT
|
Beat with the hammer through a copper or brass drift an internal ring of the CV JOINT (fig. 3.120).
Ventilation of a boot of the hinge
At installation of a protective cover of the hinge in it the lowered pressure can be formed.
At the movement it causes formation of a fold.
|
Fig. 3.121. Alignment of pressure at installation of a protective cover of the hinge
|
For prevention of it, it is necessary to level pressure before putting on of a collar, having raised a protective cover of the hinge (fig. 3.121).
|
Fig. 3.122. The provision of an expansion ring and dish-shaped spring (from a wheel): 1 – lock ring; 2 – dish-shaped spring; 3 – expansion ring (plastic)
|
NOTE
The management treats only collars from stainless steel.
|
Compression of a collar on the external hinge
|
Fig. 3.123. Compression of a collar on the external hinge
|
Establish pincers of V.A.G 1682, as shown in the figure 3.123. At the same time it is necessary to watch that blooming edges of pincers adjoined to the ledge basis B collars.
Press out a collar, having turned the running screw a dynamometer key (without turning pincers).
Inhaling moment: 20 N · m.
Use a dynamometer key with a range of regulation of 5-50 N · m (for example a dynamometer key).
You watch that the running screw of pincers moved without jammings. If necessary put a small amount of MOS 2 lubricant.
At the complicated rotation, for example, owing to pollution of a carving, at the specified moment of an inhaling the necessary effort of compression of a collar is not reached.
|